New & Genuine OMRON SHL-Q2255 Panel Mount Roller PlungerProduct Specification:
Shape / Structure
Enclosed Limit switches
service life
General type
Operating mechanism
Snap action
Actuator
Panel mount roller plunger
Frequency
50/60 Hz
Switching mechanism
Self-reset mechanism
Contact configuration
Single-Pole, Double-Throw type
Contact form
SPDT
Load
General load
Ratings (AC): Non-Inductive load
Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 480 VAC, Resistive load: 2 A (NC) 2 A (NO)
Ratings (AC): Inductive load
Rated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2.5 A (NC) 2.5 A (NO)
Rated voltage: 250 VAC, Inductive load: 2 A (NC) 2 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
Ratings (DC): Non-Inductive load
Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
Rated voltage: 30 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO)
Rated voltage: 250 VDC, Resistive load: 0.2 A (NC) 0.2 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO)
Ratings (DC): Inductive load
Rated voltage: 8 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
Rated voltage: 14 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
Rated voltage: 30 VDC, Inductive load: 1.5 A (NC) 1.5 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO)
Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO)
Explanation
The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current.
Inrush current
NC: 15 A
NO: 15 A
Protective circuit
Classification of protection against electric shock: Class II (Double insulation)
Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
Ambient temperature
Operating: -10 to 80 CEL
(with no icing or condensation)
Ambient humidity
Operating: 35 to 95%RH
(with no icing or condensation)
Characteristics
Permissible operating speed
0.1 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically)
120 operations / 1 minute Max.
Permissible operating frequency (Electrically)
30 operations / 1 minute Max.
Contact resistance
15 mOhm Max. (Initial value)
(Measuring method is contact resistance meter.)
Insulation resistance
Between each terminal of the same polarities: 100 MOhm Min.
Between live-metallic part and ground: 100 MOhm Min.
Between each terminal and non-live-metallic part: 100 MOhm Min.
(at 500 VDC Megger)
Dielectric strength
Between each terminal of the same polarities: 1,000 VAC
Between live-metallic part and ground: 2,000 VAC
Between each terminal and non-live-metallic part: 2,000 VAC
(50/60 Hz for 1 min)
Durability (Mechanically)
10,000,000 operations Min. (No load)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Durability (Electrically)
500,000 operations Min. (Resistive load 10 A at 125 VAC)
(Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
Pollution degree
3 (EN60947-5-1)
Vibration resistance (Malfunction)
Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction)
1,000 m/s2
Shock resistance (Malfunction)
Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
Degree of protection
IEC60529 (JEM): IP67
NEMA250: Type1
Applicable standard (UL)
Standard No.: UL508
File number: E76675
Applicable standard (CSA)
Standard No.: C22.2 NO.14
File number: LR45746
Applicable standard (TUV)
Standard No.: EN60947-5-1
File number: J50062486
Applicable standard (CCC(CQC))
Standard No.: GB14048.5
File number: 2003010305072162
Applicable standard (EC Directive (Low Voltage Directive) )
2006/95/EC
Mounting specification
Panel mounting, Side mounting
Operating characteristics
Operating Force (OF)
Standard value 9.81 N Max.
Release Force (RF)
Standard value 1.96 N Min.
Pre-Travel (PT)
Standard value 1.5 mm Max.
Over-Travel (OT)
Standard value 2 mm Min.
Movement Differential (MD)
Standard value 0.5 mm Max.
Operating Position (OP)
Standard value 43 +/- 0.8 mm
Package Include:
1 x NEW OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load6 months warranty
60 days money back